Pulsair desktop Tonometer

4500.00 CHF
Devices
11 months
As New
Sell
Switzerland
Valais
ID: 22
Published 11 months ago by Tecnilabz
4500.00 CHF
In Devices category
As New
Sell
Martigny, Valais, Switzerland
Get directions →
Technical specifications of the Keeler Pulsair Desktop :
- Calibration range: 5 mmHg to 50 mmHg
- Display accuracy: Display accurate to 1 digit after the decimal point; e.g. 12.3
- Display type: Alphanumeric, 16 characters, single line
- Illumination system: Infrared LEDs
- Working distance: 20 mm
- Dimensions: 475 x 410 x 245 mm (H x D x W)
- Weight: 16 kg

Year 2023

- Compliance with BS EN 60601-1:2006 electrical (medical) protection standards.
- Electromagnetic compatibility EN 60601-1-2:2007.
- Ophthalmic instruments - Fundamental requirements and test methods ISO 15004-1:2006. - Optical radiation hazards ISO 15004-2:2007
- Switched-mode power supply (110 - 240 V) +/- 10% multi-socket type compliant with EN 60601-1 EN 61000-6-2, EN 61000-6-3
- 30 VA output power (12 V DC 2.5 A)
- 50/60 Hz frequency
- Thermal printer, line by line Read more

Published on 24/02/2025

    Attributes

  • Brand
    Keeler
  • Model
    Pulsair
  • Warranty
    0
  • Delivery
    Switzerland

Description

Technical specifications of the Keeler Pulsair Desktop :
- Calibration range: 5 mmHg to 50 mmHg
- Display accuracy: Display accurate to 1 digit after the decimal point; e.g. 12.3
- Display type: Alphanumeric, 16 characters, single line
- Illumination system: Infrared LEDs
- Working distance: 20 mm
- Dimensions: 475 x 410 x 245 mm (H x D x W)
- Weight: 16 kg

Year 2023

- Compliance with BS EN 60601-1:2006 electrical (medical) protection standards.
- Electromagnetic compatibility EN 60601-1-2:2007.
- Ophthalmic instruments - Fundamental requirements and test methods ISO 15004-1:2006. - Optical radiation hazards ISO 15004-2:2007
- Switched-mode power supply (110 - 240 V) +/- 10% multi-socket type compliant with EN 60601-1 EN 61000-6-2, EN 61000-6-3
- 30 VA output power (12 V DC 2.5 A)
- 50/60 Hz frequency
- Thermal printer, line by line

Meet the seller

Tecnilabz
Rue de la Riaz 11, 1026, Echandens, Vaud, Switzerland
101 active listings
Company
Last online 1 month ago
Registered for 1 year

Comments (0)

No comments has been added yet
Add comment

Recently viewed

Tecnilabz Pro Tecnilabz 7 months
Pro Incubator Martigny Valais 7 months
Incubateur de transport Airborne Pulseox 750l
5000.00 CHF
Incubateur de transport Airborne Pulseox 750l
Martigny
Incubateur de transport Airborne Pulseox 750l
7 months Good Sell Incubator
5000.00 CHF
Tecnilabz Pro Tecnilabz 7 months
Pro Chairs Martigny Valais 7 months
Poste de travail gynécologique
13000.00 CHF
Poste de travail gynécologique
Martigny
Le poste de travail gynécologique GRACIE crée un environnement attrayant pour le médecin et le patient tout en privilégiant l'ergonomie et l'efficacité de l'examen. Il est composé de : 1/ CHAISE GYNÉCOLOGIQUE AVEC REPOSE-JAMBES : Des contrôles sans ambiguïté permettent gagner du temps et augmenter le niveau de certitude du médecin lors de l'examen. Facilité ...
7 months Good Sell Chairs
13000.00 CHF
Tecnilabz Pro Tecnilabz 11 months
Pro Consultations Martigny Valais 11 months
Topcon ACP-8 test projector
735.00 CHF
Topcon ACP-8 test projector
Martigny
Test projector with remote control
11 months Good Sell Consultations
735.00 CHF
Tecnilabz Pro Tecnilabz 11 months
ERBE VIO 200d with trolley
1800.00 CHF
ERBE VIO 200d with trolley
Martigny
- Functionality : Monopolar cutting, Bipolar cutting, Bipolar coagulation, Monopolar coagulation - Technology: radio frequency - Cutting power Max: 200 W Min: 0 W - Coagulation power Max: 120 W Min: 0 W
11 months Good Sell Electrosurgery
1800.00 CHF
Tecnilabz Pro Tecnilabz 7 months
Pro Monitoring Martigny Valais 7 months
Datex Ohmeda S5
4250.00 CHF
Datex Ohmeda S5
Martigny
ECG, PNI, SPO2, t°, Resp, PI et CO2, gaz halogénés
7 months Good Sell Monitoring
4250.00 CHF
Call Sms Send message
Are you a professional seller? Create an account
13/02/2026 - 11:41:22 [ OPERATION OK ] Connected to 'jw0mwg_app_osclass': [DBHOST] = jw0mwg.myd.infomaniak.com | [DBUSER] = jw0mwg_osclass
13/02/2026 - 11:41:22 [ OPERATION OK ] SELECT user_id, pic_ext FROM bta3_t_profile_picture WHERE user_id = '2'
13/02/2026 - 11:41:22 [ OPERATION OK ] Connection with 'jw0mwg_app_osclass' released properly